Laboratory Equipment Pharmaceutical Refrigerator Operational Last updated 2026-05-18 Current location Laboratory Core details Asset ID MT-008 Department Laboratory Device type Pharmaceutical Refrigerator Location — Manufacturer Haier Biomedical Model HYC-410 Serial number BEUK 0E000QER2 R0038 Year 2025 Responsible — Ownership Purchase Technical Power 220V-240V 350W Connectivity — Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2026-01-23 PM Maintenance Haier — 2026-04-23 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Refrigerator an Freezer Operational Last updated 2026-05-18 Current location Laboratory Core details Asset ID MT-009 Department Laboratory Device type Refrigerator an Freezer Location — Manufacturer Haier Biomedical Model HYCD-469 Serial number BE01 30AR0 0QJM7 D0032 Year 2021 Responsible — Ownership Purchase Technical Power 220V 600W 3.1A Connectivity — Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Qingdao Haier Biomedical CO., Ltd, Haier Insdustrial Park Economic Technology Developement Zone, Qingdao, P.R. China Escalation — Temperature Water Tank Operational Last updated 2026-05-18 Current location — Core details Asset ID MT-010 Department Laboratory Device type Water bath Location — Manufacturer n/a Model WB 3-1 Serial number 20112562 Year 2011 Responsible — Ownership — Technical Power 220V 800W Connectivity — Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintenance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Blood Gas and Chemistry Analyzer Operational Last updated 2026-05-18 Current location ICU Core details Asset ID MT-022 Department ICU Device type Blood Gas and Chemistry Analyzer Location ICU Manufacturer EDAN Model i15 Serial number 960360-M24A13900005 Year 2024 Responsible — Ownership Purchase Technical Power 19V 13.5A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Oscilistor Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-024 Department Laboratory Device type Oscilitator Location Laboratory Manufacturer n/a Model KJ-201BD Serial number n/a Year n/a Responsible — Ownership — Technical Power — Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintainance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Roll Mixer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-025 Department Laboratory Device type Roll Mixer Location Laboratory Manufacturer n/a Model n/a Serial number n/a Year n/a Responsible — Ownership — Technical Power — Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintainance EK — 2025-09-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Microscope Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-026 Department Laboratory Device type Microscope Location Laboratory Manufacturer Olympus Model CX21FS1 Serial number 8K07186 Year n/a Responsible — Ownership Purchase Technical Power 100-240V 0.42/0.25A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintainance EK — 2025-09-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Electric Centrifuge Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-027 Department Laboratory Device type Electric Centrifuge Location Laboratory Manufacturer n/a Model 80-1 Serial number 8K07186 Year n/a Responsible — Ownership — Technical Power n/a Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintainance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Urine Analyzer Operational Last updated 2026-05-20 Current location — Core details Asset ID MT-28 Department Laboratory Device type URINE ANALYZER Location Laboratory Manufacturer n/a Model URIT-50 Serial number 50-21641E Year 2021 Responsible — Ownership — Technical Power 12V 30VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — PM — — — — Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Auto Hematology Analyzer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-29 Department Laboratory Device type Auto Hematology Analyzer Location Laboratory Manufacturer Genrui Model KT-6610 Serial number 0820303221662 Year 2022 Responsible — Ownership Purchase Technical Power 100-204V 200VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-11-28 PM Maintenance Action Medeor — 2026-05-16 Notes Known issues — Spare parts on-site — Vendor / technician contact Genuri Biotech Inc. 4-10F, Bulding 3, Geya Technology Park, Guangming District, 518106 Shenzhen, China Escalation — Auto Hematology Analyzer Out of service Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-30 Department Laboratory Device type Auto Hematology Analyzer Location Laboratory Manufacturer TECCOM Science Corporation Model TEK5000P Serial number C9-E0437 Year 2021 Responsible — Ownership Purchase Technical Power 100-204V 150VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact TECCOM Science Corporation 555#, Gaoxin Ave, National Hi-tech Ind Development Zone, Nanchang, Jianxi 330096, P.R. China Escalation — Chemistry Analyzer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-31 Department Laboratory Device type Chemistry Analyzer Location Laboratory Manufacturer Midray Model BS-230 Serial number YY-11002066 Year 2021 Responsible — Ownership — Technical Power 220-240V 1000VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-05-27 PM Maintenance — — 2025-11-01 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Electrolyte Analyzer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-32 Department Laboratory Device type Electrolyte Analyzer Location Laboratory Manufacturer Genrui Model GE300 Serial number 1350111245674 Year 2024 Responsible — Ownership Purchase Technical Power 220-240V 80VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-12-15 PM Maintanance — — 2026-06-14 Notes Known issues — Spare parts on-site — Vendor / technician contact Genuri Biotech Inc. 4-10F, Bulding 3, Geya Technology Park, Guangming District, 518106, Shenzen China Escalation — Chromatograph Operational Last updated 2026-05-20 Current location — Core details Asset ID MT-33 Department Laboratory Device type Chomatorgraph Location Laboratory Manufacturer Boditech Med Inc. Model iChroma II Serial number IR2RC262053 Year 2021 Responsible — Ownership Purchase Technical Power 220-240V 80VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-03-15 PM Maintanance Hypermed Health Care — 2025-09-15 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Temerature Auxiliary Device Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-34 Department Laboratory Device type Temerature Auxiliary Device Location Laboratory Manufacturer Boditech Med Inc. Model i-chamber Serial number ICMQB140424 Year 2020 Responsible — Ownership Purchase Technical Power 12V 5A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Boditech Med Inc. 43, Geodudanji 1-gil, Dongnae-myeon, Chuncheon-si, Gang-won-do 243998 Korea Tel: +82332431400 Escalation — Coagulometer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-35 Department Laboratory Device type Coagulometer Location Laboratory Manufacturer Erba Model ECL 105 Serial number E0620-11-141021 Year 2021 Responsible — Ownership Purchase Technical Power 7.5V 5.35A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintanance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact Erba Lachema s.r.o. Karasek 2219/1d 621 00 Brno, CZ Escalation — Centrifuge Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-36 Department Laboratory Device type Centrifuge Location Laboratory Manufacturer Nuve Model NF 1200 Serial number 03.1739 Year 2018 Responsible — Ownership — Technical Power 230V 500W Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintanance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact Saracalar Mah Saracalar Kume Evieri No. 4/2 Akyurt 06750 Ankara Turkiye, TEL: +90 312 399 28 30 E-Mail: sales@nuve.com.tr Escalation — Pima Analyser Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-37 Department Laboratory Device type Pima Analyser Location Laboratory Manufacturer Alere Technologies GmbH Model n/a Serial number PIMA-D-001495 Year n/a Responsible — Ownership Purchase Technical Power n/a Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Alere Technologies GmbH Loebstedter Str.103-105 D-00749 Jena, Germany www.pimatest.com Escalation — Analyser Operational Last updated 2026-05-20 Current location — Core details Asset ID MT-38 Department Laboratory Device type Analyser Point of Care Location Laboratory Manufacturer Abbott Diagnostics Technologies AS Model Afinion 2 Serial number AF20078380 Year 2024 Responsible — Ownership Purchase Technical Power 24V 1.7A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due 2025-06-08 PM Maintenance EK — 2025-12-08 Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Universal Printer Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-39 Department Laboratory Device type Universal Printer Location Laboratory Manufacturer Alere Model BTP-L560 Serial number 2012A711892 Year 2012 Responsible — Ownership Purchase Technical Power 24V 1.5A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Shandong New Beiyang, Information Technology Co. Ltd., 169 Huoju Road, HDZ, 264209 Weiahi Shandong, China Escalation — Chemistry Analyzer Out of service Last updated 2026-05-20 Current location — Core details Asset ID MT-40 Department Laboratory Device type Chemistry Analyzer Location Laboratory Manufacturer Sinothinker Technology Co. Ltd. Model SK3002B Serial number sn3002B112111503 Year 2022 Responsible — Ownership Purchase Technical Power 220VAC PC: 12VDC 6A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — PM — — — — Notes Known issues — Spare parts on-site — Vendor / technician contact — Escalation — Chemistry Analyzer Out of service Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-41 Department Laboratory Device type Chemistry Analyzer Location Laboratory Manufacturer Dirui Industrial Co. Ltd. Model DR-7000D Serial number S197000DDR0430 Year 2022 Responsible — Ownership Purchase Technical Power 100-240V 85VA Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Dirui Industrial Co. Ltd. 95 Yunhe Street, New & Hight Tech. Development Zone, Changchun, Jilin 130012, P.R. China Escalation — Drying Camber Operational Last updated 2026-05-20 Current location Laboratory Core details Asset ID MT-42 Department Laboratory Device type Drying Camber Location Laboratory Manufacturer Binder Model E28 Serial number 08-44431 Year 2022 Responsible — Ownership Donation Technical Power 230V 3.5A Connectivity none Other — Software — Consumables — Maintenance log PM = Preventive maintenance, CM = Corrective maintenance Date Type Action By Ref/Ticket Next due — no entries yet — Notes Known issues — Spare parts on-site — Vendor / technician contact Binder D-78532 Tuttlingen Germany, TEL: +490746220050 Escalation —